Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 119
Filter
1.
Chinese Journal of Biotechnology ; (12): 1684-1695, 2023.
Article in Chinese | WPRIM | ID: wpr-981163

ABSTRACT

C-fos is a transcription factor that plays an important role in cell proliferation, differentiation and tumor formation. The aim of this study was to clone the goat c-fos gene, clarify its biological characteristics, and further reveal its regulatory role in the differentiation of goat subcutaneous adipocytes. We cloned the c-fos gene from subcutaneous adipose tissue of Jianzhou big-eared goats by reverse transcription-polymerase chain reaction (RT-PCR) and analyzed its biological characteristics. Using real-time quantitative PCR (qPCR), we detected the expression of c-fos gene in the heart, liver, spleen, lung, kidney, subcutaneous fat, longissimus dorsi and subcutaneous adipocytes of goat upon induced differentiation for 0 h to 120 h. The goat overexpression vector pEGFP-c-fos was constructed and transfected into the subcutaneous preadipocytes for induced differentiation. The morphological changes of lipid droplet accumulation were observed by oil red O staining and bodipy staining. Furthermore, qPCR was used to test the relative mRNA level of the c-fos overexpression on adipogenic differentiation marker genes. The results showed that the cloned goat c-fos gene was 1 477 bp in length, in which the coding sequence was 1 143 bp, encoding a protein of 380 amino acids. Protein structure analysis showed that goat FOS protein has a basic leucine zipper structure, and subcellular localization prediction suggested that it was mainly distributed in the nucleus. The relative expression level of c-fos was higher in the subcutaneous adipose tissue of goats (P < 0.05), and the expression level of c-fos was significantly increased upon induced differentiation of subcutaneous preadipocyte for 48 h (P < 0.01). Overexpression of c-fos significantly inhibited the lipid droplets formation in goat subcutaneous adipocytes, significantly decreased the relative expression levels of the AP2 and C/EBPβ lipogenic marker genes (P < 0.01). Moreover, AP2 and C/EBPβ promoter are predicted to have multiple binding sites. In conclusion, the results indicated that c-fos gene was a negative regulatory factor of subcutaneous adipocyte differentiation in goats, and it might regulate the expression of AP2 and C/EBPβ gene expression.


Subject(s)
Animals , Goats/genetics , Cell Differentiation/genetics , Adipogenesis/genetics , Gene Expression Regulation , Proteins/genetics , Cloning, Molecular
2.
RGO (Porto Alegre) ; 71: e20230058, 2023. graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1521439

ABSTRACT

ABSTRACT Mechanical liposuction of cervicomental fat is part of the aesthetic procedures of orofacial harmonization. Ultrasonography stands out for illustrating soft tissues with high-resolution images in the diagnostic and postoperative stages. The present study aimed to report the case of a female patient, 54 years old, in good general health, confirmed by all previously requested laboratory tests, whose main complaint was the presence of excess fat in the jowl region. The stages after the liposuction procedure were followed by high-resolution ultrasound examinations in order to assess the healing of the manipulated tissues, and ultrasound evaluations were performed in the postoperative follow-up periods of 30, 60 and 120 days. Through the present study, it was possible to conclude that ultrasonography is an important ally in the postoperative follow-up of neck liposuction, allowing to follow the evolution of the post-surgical repair process.


RESUMO A lipoaspiração mecânica da gordura cervical faz parte dos procedimentos estéticos de harmonização orofacial. A ultrassonografia se destaca por evidenciar tecidos moles com imagens de alta resolução nas fases diagnóstica e pós-operatória. O presente estudo teve como objetivo relatar o caso de uma paciente do sexo feminino, 54 anos, com bom estado geral de saúde, confirmado por todos os exames laboratoriais previamente solicitados, cuja queixa principal era a presença de excesso de gordura na região da papada. As etapas após o procedimento de lipoaspiração foram acompanhadas por exames ultrassonográficos de alta resolução para avaliar a cicatrização dos tecidos manipulados e as avaliações ultrassonográficas foram realizadas nos períodos de acompanhamento pós-operatório de 30, 60 e 120 dias. Através do presente estudo foi possível concluir que a ultrassonografia é uma importante aliada no acompanhamento pós-operatório de lipoaspiração cervical, permitindo acompanhar a evolução do processo de reparo pós-cirúrgico.

3.
Surg. cosmet. dermatol. (Impr.) ; 15: e20230181, 2023.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1438330

ABSTRACT

A esclerodermia localizada (morfeia linear) é uma doença rara que causa distrofia e assimetria faciais em mulheres jovens. É relatado o caso de uma paciente de 20 anos que foi tratada com enxertos compostos de gordura. Após a coleta do lipoaspirado de gordura subcutânea profunda, a microgordura e a nanogordura não filtrada foram processadas separadamente para formar enxertos compostos de gordura. Estes foram meticulosamente transplantados em camadas, para reconstruir o subcutaneo da face da paciente. Após um ano, observou-se boa pega de gordura com correção bem-sucedida da assimetria e restabelecimento do equilíbrio facial.


Localized scleroderma (linear morphea) is a rare disease that causes facial dystrophy and asymmetry in young women. We report the case of a 20-year-old female patient who was treated with novel composite fat grafts. After extracting lipoaspirate from deep subcutaneous fat, the microfat and the unfiltered nanofat were processed separately, and amalgamated, obtaining composite fat grafts. These were meticulously transplanted layer by layer to rebuild the subcutaneous tissue of the patient's face. After one year, a good volume of fat retention was observed with successful correction of asymmetry and restoration of facial balance.

4.
Rev. bras. cir. plást ; 37(3): 277-282, jul.set.2022. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1398683

ABSTRACT

Introdução: A evolução da técnica de lipoaspiração e da enxertia de gordura associada a segurança oncológica permitiram utilizar a gordura como preenchedor autólogo em pacientes com neoplasia de mama que eram submetidas a reconstrução mamária. O objetivo é apresentar uma inovação no instrumento de coleta de gordura que será utilizada como enxerto, para uso em reconstrução mamária. Métodos: Foi realizada a busca de anterioridade nos bancos de dados internacionais e nacional e a confecção de um protótipo de cânula de coleta de gordura de 35cm de comprimento, com diâmetro do tubo de 4mm, com 10 furos redondos na sua extremidade distal com 2mm de diâmetro. Foi realizado um experimento de aspiração de substância viscosa comparando o protótipo com dois modelos de cânulas com desenho padrão da indústria, de três furos tipo Mercedes e de cinco furos tipo Pitanguy. Resultados: Foram encontrados quatro patentes de alta relevância e uma patente de média relevância, que diferem do modelo de utilidade proposto quando se comparam o tipo de desenho da extremidade distal das cânulas estudadas e a função dos instrumentos identificados. Quando comparou-se a eficiência do protótipo, a cânula de cinco furos foi a mais eficiente na aspiração da substância viscosa, e não houve diferença estatística na velocidade de aspiração entre o protótipo e a cânula de três furos tipo Mercedes. Conclusão: A inovação apresentada para a coleta de enxerto de gordura para uso em reconstrução mamária apresentou a mesma eficiência que a cânula Mercedes de três furos neste modelo experimental.


Introduction: The evolution of liposuction and fat graft technique with the oncologic safety allowed to use the fat as autologous filler in patients with breast cancer and submitted to breast reconstruction. The objective is to introduce an innovation in the instrument used to harvest fat grafts for breast reconstruction. Methods: Search of anteriority and trademarks were performed at international and national databases, and a prototype was built as a fat harvest instrument with 35cm in length, 4cm in diameter, with 10 holes at the distal extremity, with 2mm diameter each. It was experimented with a harvest of a viscous substance, comparing the prototype with two regular industry cannulas types: three holes Mercedes' type and five roles Pitanguy's type. Results: Four high-relevance patents and one medium-relevance patent were found, which differ from the proposed utility model when comparing the type of design of the distal end of the studied cannulas and the function of the instruments identified. When the prototype's efficiency was compared with the other cannulas, the cannula with five holes in Pitanguy's type was the most efficient, and it was no statistical difference between the prototype and the cannula with three roles in Mercedes' type. Conclusion: The innovation presented to harvest fat graft for breast reconstruction had the same efficiency in harvesting the viscose substance as the cannula Mercedes type with three holes in this experimental model.

5.
Rev. bras. cir. plást ; 37(2): 169-176, abr.jun.2022. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1379741

ABSTRACT

Introdução: O conceito da estética feminina vem apresentando mudanças, com forte influência dos padrões culturais e regionais. Glúteos e mamas são as principais regiões enfatizadas, principalmente na América Latina. Diante disto, a lipoenxertia glútea adquire uma importância crescente. Neste trabalho, objetivamos estudar os resultados deste procedimento e suas complicações, sugerir uma classificação do formato dos glúteos e padronização de áreas a serem tratadas com a lipoenxertia. Métodos: Trata-se de um estudo prospectivo, realizado de janeiro de 2018 a fevereiro de 2020, com seguimento pós-operatório mínimo de 6 meses. Foi utilizada a técnica tumescente para obtenção da gordura, tratada por decantação, e injetada com seringa e cânula via sulco interglúteo e sulco subglúteo. Resultados: Dos 146 pacientes, nove foram excluídos, restando 137, sendo 132 mulheres e cinco homens. A idade média dos pacientes foi de 34,1 anos e o índice de massa corporal médio foi de 27,2Kg/m2. O formato de glúteo predominante foi o trapezoide (52,5%) e o volume médio de gordura injetado nos glúteos foi de 510,8ml no lado direito e 580,5ml no esquerdo, sendo as áreas central e lateral do glúteo as mais enxertadas. Quanto às complicações, a assimetria ocorreu em 3,65% dos pacientes, bolhas na pele em 2,9% e dor crônica em 2,2% deles. Conclusão: É um procedimento seguro com baixa incidência de complicações, quando é respeitada a restrição ao subcutâneo como plano de lipoenxertia, e de alta satisfação para os pacientes. A classificação e padronização sugeridas podem auxiliar a aprendizagem do procedimento.


Introduction: The concept of female aesthetics has been changing, strongly influenced by cultural and regional patterns. Buttocks and breasts are the main regions emphasized, especially in Latin America. Then, gluteal fat grafting becomes increasingly important. In this article, we aim to study the results of this procedure and its complications, suggest a classification of the shape of the buttocks and standardize areas to be treated with fat grafting. Methods: This is a prospective study realized from January 2018 to February 2020, and there was a follow-up of the patients for 6 months of postoperative. The surgical technique was tumescent to get fat, and decantation was the method to prepare the graft, which was injected through the intergluteal and subgluteal folds. Results: Of 146 patients, nine were excluded, remaining 137, of which 132 were women, and four were men. The mean age of patients was 34.1 years, and the mean body mass index was 27.2Kg/m2. The predominant gluteal shape was the trapezoid (52.5%), and the average volume of fat injected into the buttocks was 510.8ml on the right side and 580.5ml on the left, with the central and lateral gluteal areas being the most grafted. As for complications, asymmetry occurred in 3.65% of patients, skin blister in 2.9% and chronic pain in 2.2% of them. Conclusion: It is a safe procedure with a low incidence of complication when the fat grafting respects the subcutaneous plane, and this procedure has high patient satisfaction.

6.
Int. j. cardiovasc. sci. (Impr.) ; 35(1): 39-45, Jan.-Feb. 2022. tab
Article in English | LILACS | ID: biblio-1356317

ABSTRACT

Abstract Background: Abdominal obesity has been associated with cardiovascular disease and may be modulated by dietary intake. The deep abdominal subcutaneous adipose tissue (dSAT) is a body fat compartment that can be estimated by using mathematical formulas. Objectives: To evaluate the association between dSAT estimated by the Deep-Abdominal-Adipose-Tissue (DAAT) index and dietary intake in patients with acute coronary syndrome (ACS). Methods: This is a cross-sectional study conducted with patients ≥ 18 years of age admitted to a tertiary hospital. Sociodemographic, clinical, and anthropometric (body weight [kg], height [m], waist, hip and neck circumferences [cm]) data were evaluated. A food frequency questionnaire was applied to identify each patient's nutrient intake. The DAAT index was calculated according to specific formulas for men and women. Possible association between food intake and the DAAT index was evaluated by multiple linear regression. The level of significance adopted was 0.05. Results: This study evaluated 138 patients, with a mean age of 61.2±10.8 years. Prevalence of obesity was 29.4% in men and 37.7% in women. Regarding waist circumference, 83% of the women showed values considered to be very high. The DAAT index was significantly higher in men when compared to woman (P < 0.0001) and proved to be positively correlated with proteins (r= 0.22, P= 0.01) and monounsaturated fatty acid (r= 0.18, P= 0.04) intake in the entire sample. After adjustment for sex, alcohol consumption, and levels of physical activity, the DAAT index was associated with the female sex (B= −129.84, P <0.001) and a sedentary lifestyle (B= 57.99, P <0.001). Conclusion: dSAT estimated by the DAAT index was not associated with dietary intake in patients with ACS.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Eating/physiology , Subcutaneous Fat, Abdominal , Acute Coronary Syndrome , Alcohol Drinking , Exercise , Cross-Sectional Studies , Diet , Waist Circumference , Obesity, Abdominal/etiology , Sedentary Behavior , Myocardial Infarction
8.
Journal of Environmental and Occupational Medicine ; (12): 1083-1088, 2022.
Article in Chinese | WPRIM | ID: wpr-960528

ABSTRACT

Background Exercise during pregnancy is closely related to maternal and infant health. Previous studies in developed countries have linked maternal exercise during pregnancy with newborn body weight as well as subcutaneous fat thickness. However, the relevant studies in China are limited, and the conclusions remain inconsistent. Objective To investigate the effects of maternal exercise during pregnancy on neonatal weight and subcutaneous fat thickness. Methods Based on the Shanghai Birth Cohort, 959 maternal-infant pairs were included in this study. The International Physical Activity Questionnaire was used to collect average weekly frequency and daily minutes of walking in the first and second trimesters, and entropy weight method was used to calculate the cumulative exercise index in the two trimesters. Birth weight was measured using a calibrated weigh scale. Subcutaneous fat thickness was measured at abdomen, scapula, and triceps with a Harpenden skinfold caliper for all newborns and the sum of the thickness for the three sites was then calculated. A multiple linear regression model was employed to estimate the relationships of cumulative exercise index during pregnancy with neonatal body weight and subcutaneous fat thickness. Subgroup analyses stratified by pre-pregnancy body mass index (BMI) and sex of newborns were also performed. Results The mean age of pregnant women was (28.5±3.8) years, and the pre-pregnancy BMI was (21.4±3.0) kg·m−2. Newborn boys were slightly more than newborn girls (54.3% vs 45.7%), and the neonatal weight was (3374.0±427.5) g. The means of newborns' abdominal, scapular, and triceps subcutaneous fat thickness were (4.4±1.3), (5.4±1.4), and (6.0±1.5) mm, respectively, and the sum of subcutaneous fat thickness was (15.8±3.9) mm. In the first and second trimesters, 77.3% and 88.7% of pregnant women walked 4 d per week and more, respectively; the daily minutes of walking was (36.9±27.2) min and (43.3±26.3) min, respectively; the cumulative exercise index was 25.6±17.7 and 35.9±21.1, respectively. The results of multiple linear regression analysis showed that the cumulative exercise index in the second trimester was negatively associated with newborns' abdominal (b=−0.006, 95%CI: −0.010-−0.003), scapular (b=−0.005, 95%CI: −0.009-−0.002), triceps (b=−0.006, 95%CI: −0.010-−0.002), and their sum of (b=−0.018, 95%CI: −0.028-−0.007) subcutaneous fat thickness (P<0.05); in the first and second trimesters, however, the relationship between maternal cumulative exercise and newborns' body weight was not significant. The results of stratified analyses showed that the negative associations between maternal cumulative exercise index and newborns' subcutaneous fat thickness for the second trimester remained significant in the subgroups of boys and neonates whose mothers had normal pre-pregnancy BMI (P<0.05). Conclusion Cumulative exercise index in the second trimester is negatively correlated with the neonatal thickness of subcutaneous fat, and the association may be altered by neonatal sexes and maternal pre-pregnancy BMI levels.

9.
Rev. cuba. med. gen. integr ; 38(3): e1973, 2022. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1408718

ABSTRACT

Introducción: La adiposidad central como factor desencadenante de resistencia a la insulina precoz constituye una amenaza potencial de riesgo metabólico y cardiovascular en el embarazo. Objetivo: Determinar la capacidad discriminante de las grasas abdominales sobre la resistencia a la insulina, diagnosticada por el índice triglicéridos/glucosa-IMC al finalizar el primer trimestre del embarazo. Métodos: Se realizó un estudio observacional analítico de 526 gestantes con embarazo simple y edad gestacional entre 12 y 13 semanas, entre los años 2016 y 2020. Se estudió el test de triglicéridos/glucosa-IMC y las grasas abdominales por ultrasonido. Se utilizaron las curvas ROC (Receiver operating characteristic Curve) para discriminar la resistencia a la insulina al finalizar el primer trimestre de la gestación, cuando aumentan las grasas abdominales. Resultados: La grasa subcutánea fue la que presentó mayor área bajo la curva en la discriminación de la resistencia a la insulina, con un nivel de sensibilidad y especificidad aceptable. Conclusiones: La grasa subcutánea, aunque con bajo valor discriminativo, puede considerarse como augurio de resistencia a la insulina y de diabetes gestacional. Se requiere profundizar en el estudio de las grasas abdominales dado el conocimiento de su impacto en los desórdenes metabólicos en el curso avanzado de la gestación(AU)


Introduction: Central adiposity as a triggering factor for early insulin resistance is a potential threat of metabolic and cardiovascular risk in pregnancy. Objective: To determine the discriminating capacity of abdominal fat over insulin resistance, diagnosed by the triglyceride/glucose-BMI index at the end of the first trimester of pregnancy. Methods: An analytical and observational study was carried out with 526 pregnant women of singleton pregnancy and gestational age between twelve and thirteen weeks, between 2016 and 2020. The triglyceride/glucose-BMI test was studied, together with abdominal fats by ultrasound. ROC (receiver operating characteristic) curves were used to discriminate insulin resistance at the end of the first trimester of gestation, when abdominal fats increase. Results: Subcutaneous fat presented the highest area under the curve in the discrimination of insulin resistance, with an acceptable level of sensitivity and specificity. Conclusions: Subcutaneous fat, although with low discriminative value, can be considered as a harbinger of insulin resistance and gestational diabetes. Further study of abdominal fat is required, given the knowledge of its impact on metabolic disorders in late gestation(AU)


Subject(s)
Humans , Female , Pregnancy , Pregnancy Trimester, First , Insulin Resistance/physiology , Subcutaneous Fat, Abdominal/metabolism , Obesity, Abdominal/metabolism , Triglycerides/blood , Blood Glucose/analysis , Body Mass Index , Cross-Sectional Studies , Predictive Value of Tests , ROC Curve
10.
Einstein (Säo Paulo) ; 20: eAO5587, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1375356

ABSTRACT

ABSTRACT Objective: To evaluate the effects of combining topiramate, bupropion and naltrexone in obesity-induced rats on their weight and subcutaneous adipose tissue. Methods: A total of 40 male Wistar rats were induced to obesity for 8 weeks and the animals were divided into 8 groups: Ctr - control, G0 - Sham, G1 - oral saline solution (1.0mL/day), G2 - topiramate (20.0mg/kg) and bupropion (5.0mg/kg), G3 - naltrexone (20.0mg/kg), G4 - topiramate (20.0mg/kg), G5 - bupropion (5.0mg/kg) and G6 - topiramate (20.0mg/kg), bupropion (5.0mg/kg) and naltrexone (20.0mg/kg). During the experiment, all animals were weighed weekly. After 30 days of treatment animals were euthanized and their skin fragments were processed and stained with hematoxylin and eosin for morphological, morphometric and biochemical analyzes. Results: The only group that presented a decrease in the volume of subcutaneous adipose tissue was G3, but this decrease was not significant when compared with the other groups. The G4, the G5 and the G6 presented increased adipose tissue volume. Data showed that until the eighth week all animals increased their weight by approximately 50%. After treatment animals of all groups, except G3, increased their weight from 4% to 9% approximately. The G3 was the only group that lost weight, but this decrease was not significant. Conclusion: The medicines studied were not efficient in reducing weight in obese rats. However, it should be considered that 30-day treatment period is not enough to observe the stronger effects of these drugs.

11.
Gac. méd. espirit ; 23(2): 39-52, 2021. tab
Article in Spanish | LILACS | ID: biblio-1339933

ABSTRACT

RESUMEN Fundamento: La obesidad abdominal en gestantes es un marcador de riesgo cardiometabólico independientemente de la adiposidad general, siendo la ultrasonografía de gran utilidad para distinguir los compartimientos adiposos del abdomen y diagnosticar tal peligro al inicio de la gestación. Objetivo: Determinar asociaciones entre variables ecográficas de adiposidad abdominal y variables analíticas y antropométricas en gestantes normopeso al inicio del embarazo según fenotipos metabólicos empleando análisis de correlación canónica. Metodología: Estudio transversal en 526 embarazadas normopeso, entre 12 y 14 semanas de edad gestacional, atendidas en consulta de ultrasonido del Policlínico Docente Chiqui Gómez, municipio Santa Clara. Se midieron las grasas abdominales subcutánea, preperitoneal y visceral, así como variables antropométricas y analíticas. Se conformaron 3 fenotipos metabólicos, y se aplicó la correlación canónica para determinar el nexo entre las mismas y su comportamiento en los diferentes fenotipos. Resultados: Se identificaron 2 conjuntos de variables con correlaciones canónicas que se incrementaron del fenotipo saludable al metabólicamente obeso con valores de 0.6930 a 0.8955 y 0.9298 respectivamente y alta significancia estadística (p=0.000). Conclusiones: Se demuestra el nexo entre las variables ecográficas de adiposidad abdominal grasa subcutánea y grasa visceral y las variables analíticas resistencia a Ia insulina, producto de acumulación lipídico, índice aterogénico y glucemia, evidenciado por los altos valores de correlaciones canónicas obtenidos según cambia el fenotipo de normopeso saludable al metabólicamente obeso; orientando un nuevo enfoque en la determinación de fenotipos de riesgo metabólico en la gestación temprana en mujeres normopeso.


ABSTRACT Background: Abdominal obesity in pregnant women is an indicator of cardiometabolic risk with non-independence of general adiposity, being the ultrasound very useful to distinguish the abdomen adipose compartments also diagnose this risk at the beginning of pregnancy. Objective: To determine possible associations between the ultrasound variables of abdominal adiposity and those analytical and anthropometric in normal-weight pregnant women at the beginning of pregnancy according to metabolic phenotypes using canonical correlation analysis. Methodology: A cross-sectional study in 526 normal-weight pregnant women, between 12 and 14 weeks of gestational age, assisted in the ultrasound office at Chiqui Gómez teaching polyclinic, in Santa Clara city. Subcutaneous, preperitoneal and visceral abdominal fats were measured, as well as anthropometric and analytical variables. Three metabolic phenotypes were formed, and canonical correlation was applied to determine their relation and also behavior among the different phenotypes. Results: 2 sets of variables were identified with canonical correlations that increased from the healthy to the metabolically obese phenotype with values from 0.6930 to 0.8955 and 0.9298 respectively and high statistical significance (p=0.000). Conclusions: The link between the ultrasound variables of abdominal adiposity, subcutaneous and visceral fat and the analytical insulin resistance, lipid accumulation product, atherogenic index and blood glucose is demonstrated, evidenced by the high values of canonical correlations obtained as the phenotype changes from healthy normal-weight to metabolically obese; guiding a new approach in the resolve of the metabolic risk phenotypes in early gestation in normal-weight women.


Subject(s)
Anthropometry , Pregnant Women , Subcutaneous Fat, Abdominal/diagnostic imaging , Adiposity
12.
Rev. colomb. cienc. pecu ; 34(2): 117-125, Apr.-June 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1394935

ABSTRACT

Abstract Background: pH, subcutaneous fat thickness (SFT), and color are fundamental variables to define the organoleptic characteristics of meat. However, multivariate relationships of those traits remain unexplored in bovine meat. Objective: To investigate the multivariate relationships among pH, subcutaneous fat thickness, and color parameters in bovine meat using canonical correlation analysis. Methods: A dataset containing 173 individual records of pH, SFT, and color parameters (a*: intensity of red color, b*: intensity of yellow color, and L*: lightness) from five Brazilian beef cut types (Breed: Nellore; cuts: acém, contrafilé, fraldinha, patinho and picanha) was constructed. Multivariate relationships between color variables (a*, b*, and L*) and chemical variables (pH and SFT) were explored using the CANCORR procedure of SAS. Results: Two canonical correlations between U (a*, b*, and L*; color variables) and V (pH and SFT; chemical variables) variates were significant (p<0.01). First and second canonical correlations were 0.463 and 0.282, respectively. Canonical weights for variates were for U1: a* = 0.707, b* = 0.406, and L* = -0.039; U2: a* = 0.364, b* = -0.898, and L* = 1.234; V1: pH = -0.376 and SFT = 0.935; V2: pH = 0.927 and STF = 0.356. Conclusion: Subcutaneous fat thickness significantly affected intensity of red and yellow colors, whereas pH significantly affected lightness. The results of this study may be useful for a better understanding of the role of muscle metabolism and its implications on the organoleptic characteristics of bovine meat.


Resumen Antecedentes: El pH, espesor de la grasa subcutánea (SFT) y color, son variables importantes que definen las características organolépticas de la carne de rumiantes. Sin embargo, su relación multivariada en carne bovina permanece inexplorada hasta ahora. Objetivo: Investigar la relación multivariada entre el pH, SFT y parámetros de color en carne bovina mediante el análisis de correlación canónica. Métodos: Se construyó una base de datos con 173 registros individuales de pH, SFT y parámetros de color (a*: intensidad de color rojo, b*: intensidad de color amarillo y L*: luminosidad) de cinco tipos de cortes de carne bovina brasileña (Raza: Nellore; cortes: acém, contrafilé, fraldinha, patinho y picanha). La relación multivariada entre las variables de color (a*, b* y L*) y las variables químicas (pH y SFT) se exploró usando el procedimiento CANCORR de SAS. Resultados: Dos correlaciones canónicas entre las variables U (compuesta por a*, b* y L*; variables de color) y V (compuesta por pH y SFT; variables químicas) fueron significativas (p<0,01). La primera y la segunda correlación canónica fueron 0,463 y 0,282, respectivamente. Los pesos canónicos para las variables canónicas fueron para U1: a* = 0,707, b* = 0,406 y L* = -0,039; U2: a* = 0,364, b* = -0,898 y L* = 1,234; V1: pH = -0,376 y SFT = 0,935; V2: pH = 0,927 y SFT = 0,356. Conclusión: El espesor de grasa subcutánea afectó significativamente la intensidad de los colores rojo y amarillo, mientras que el pH afectó significativamente la luminosidad. Los resultados de este estudio pueden ser útiles para comprender el papel del metabolismo muscular y sus implicaciones en las características organolépticas de la carne bovina.


Resumo Antecedentes: O pH, a espessura da gordura subcutânea (SFT) e a cor, são variáveis importantes que definem as características organolépticas da carne de ruminantes. No entanto, sua relação multivariada em carne bovina até o momento permanece inexplorada. Objetivo: Investigar a relação multivariada entre o pH, SFT e os parâmetros de cor em carne bovina, utilizando a análise de correlação canônica. Métodos: Foi construído um banco de dados contendo 173 registros individuais de pH, SFT e parâmetros de cor (a*: intensidade de cor vermelha, b*: intensidade de cor amarela y L*: luminosidade) de cinco tipos de cortes de carne bovina brasileira (Raça: Nellore; cortes: acém, contrafilé, fraldinha, patinho e picanha). A relação multivariada entre variáveis de cor (a *, b * e L*) e variáveis químicas (pH e SFT) foi explorada usando o procedimento CANCORR do SAS. Resultados: Duas correlações canônicas entre as variáveis U (composta de a *, b * e L *, variáveis de cor) e V (composta de pH e SFT, variáveis químicas) foram significativas (p<0,01). A primeira e segunda correlação canônica foram 0,463 e 0,282, respectivamente. Os pesos canônicos para as variáveis canônicas foram para U1: a* = 0,707, b* = 0,406 e L* = -0,039; U2: a* = 0,364, b* = -0,898 e L* = 1,234; V1: pH = -0,376 e SFT = 0,935; V2: pH = 0,927 e SFT = 0,356. Conclusão: A espessura de gordura subcutânea afetou significativamente a intensidade das cores vermelha e amarela, enquanto o pH afetou significativamente a luminosidade, em carne bovina. Os resultados deste estudo podem ser úteis para entender melhor o papel do metabolismo muscular e suas implicações nas características organolépticas da carne bovina.

13.
Arch. argent. pediatr ; 119(2): 114-122, abril 2021. tab, ilus
Article in English, Spanish | LILACS, BINACIS | ID: biblio-1151867

ABSTRACT

Introducción. La obesidad infantil puede causar hiperlipidemia y esteatosis hepática y complicaciones crónicas. Nuestro objetivo fue evaluar la relación entre el espesor de la grasa subcutánea abdominal (GSA) y la esteatosis hepática, las transaminasas y los lípidos séricos en niños obesos.Población y métodos. Estudio retrospectivo en niños (4-18 años) que acudieron a los consultorios externos. Se evaluaron las asociaciones entre el espesor de la GSA mediante ecografía y la esteatosis hepática, alanina aminotransferasa (ALT), aspartato aminotransferasa (AST) y el perfil lipídico sérico.Resultados. Se identificaron 95 niños con esteatosis hepática; el grado 1 fue el más frecuente (73,6 %, n: 70), seguido del grado 2 (21,1 %) y del 3 (5,3 %). El espesor medio (en mm) de la GSA de línea media y flancos fue 38,48 ± 11,53 y 20,91 ± 8,00 en grado 1; 41,23 ± 10,03 y 19,84 ± 6,75 en grado 2, y 63,12 ± 12,08 y 23,22 ± 5,92 en grado 3, respectivamente. El espesor de la GSA de línea media y flancos se correlacionó positivamente con triglicéridos en grado 3; el espesor de la GSA de línea media se correlacionó con el índice de masa corporal, colesterol total, colesterol LDL y AST (r: 0,9; p: 0,037; r: 0,648; p: 0,001; r: 0,387; p: 0,001; r: 0,406; p: 0,001; r: 0,463; p: 0,001; respectivamente) en grado 1.Conclusión. El espesor de la GSA mediante ecografía puede predecir hiperlipidemia en niños obesos con esteatosis hepática de grado 3 e hipercolesterolemia en grado 1.


Introduction. Childhood obesity can cause hyperlipidemia and hepatic steatosis at early age and chronic disease complications in adult life. We aimed to evaluate the relationship between abdominal subcutaneous fat thickness (ASFT) and hepatic steatosis, serum lipid and transaminase levels in obese children.Population and methods. A retrospective study was conducted with children (aged 4-18 years) who presented to outpatient clinic due to obesity. Associations between ASFT as assessed by ultrasonography (US) and hepatic steatosis, alanine transaminase (ALT), aspartate transaminase (AST) and serum lipid profile were evaluated.Results. We identified 95 children, all of which were diagnosed as having hepatic steatosis; the most common type was grade 1 (73.6 %, n: 70), followed by grade 2 (21.1 %) and grade 3 (5.3 %). The mean values of midline and flank ASFT were measured as 38.48 ± 11.53 mm and 20.91 ± 8.00 mm in grade 1; 41.23 ± 10.03 and 19.84 ± 6.75 in grade 2 and 63.12 ± 12.08 and 23.22 ± 5.92 in grade 3 hepatic steatosis, respectively. Midline and flank ASFT correlated positively with triglycerides in grade 3 steatosis, while midline ASFT correlated with body mass index, total cholesterol, low-density lipoprotein cholesterol, and AST (r: 0.9; p: 0.037; r: 0.648, p: 0.001; r: 0.387, p: 0.001; r: 0.406, p: 0.001, r: 0.463, p: 0.001; respectively) in grade 1 steatosis.Conclusion. ASFT as assessed by US may be of predictive value for hyperlipidemia in grade 3 and for hypercholesterolemia in grade 1 hepatic steatosis in obese children.


Subject(s)
Humans , Male , Child, Preschool , Child , Adolescent , Subcutaneous Fat, Abdominal/diagnostic imaging , Pediatric Obesity , Turkey/epidemiology , Retrospective Studies , Lipid Metabolism , Fatty Liver/diagnostic imaging , Transaminases
14.
Rev. bras. cir. plást ; 36(1): 2-8, jan.-mar. 2021. ilus, tab
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1151542

ABSTRACT

Introdução: A lipoaspiração é um procedimento consagrado para melhora do contorno corporal, sendo que existem diferentes tipos de laser que podem ser aplicados com o objetivo de provocar lipólise e retração da pele. Os parâmetros existentes atualmente (potência e energia) nos aparelhos permitem apenas uma inferência indireta da mudança de temperatura da pele. Métodos: Oitenta e três pacientes, entre 17 e 75 anos, foram submetidos à laserlipólise com diodo 980nm, utilizando uma termocâmera Flir® T540 para monitorização da temperatura. A lipólise foi obtida pela aplicação do laser na camada subcutânea profunda e a retração da pele na derme profunda, com velocidade de 5 centímetros por segundo. Para determinar a temperatura que provoca queimadura na pele, o laser foi aplicado na derme profunda dos retalhos abdominais das pacientes submetidas à dermolipectomia, totalizando 27 casos. Resultados: Na face medial do braço e da coxa foi utilizada uma potência de 15W e foram aplicados em média 4000J de energia por região. Na região dorsal e abdome foi adotada potência de 20W e foram aplicados 6000J em cada quadrante. No submento foram utilizados 10W e aplicados 1500J. Em média, a temperatura inicial do tecido estudado foi de 31°C, e ao final da aplicação do laser foi de 37°C. A temperatura que provocou queimadura foi 45°C. Conclusão: A utilização da termocâmera permitiu uma distribuição mais homogênea do laser e propiciou ao cirurgião uma monitorização eficaz, para que seja aplicada no subcutâneo e na derme profunda uma dose adequada de energia, obtendo-se o efeito desejado.


Introduction: Liposuction is a consecrated procedure to improve body contouring, and various types of laser can be applied to cause lipolysis and skin retraction. The current parameters (power and energy) in the devices allow only an indirect inference of skin temperature change. Methods: Eighty-three patients, between 17 and 75 years old, were submitted to laser lipolysis with 980nm diode, using a Flir® T540 thermocamera for temperature monitoring. Lipolysis was obtained by applying the laser to the deep subcutaneous layer and skin retraction in the deep dermis, with a velocity of 5 centimeters per second. The laser was used in the deep dermis of the abdominal flaps of patients undergoing dermolipectomy to determine the temperature that causes skin burns, totaling 27 cases. Results: A power of 15W was used on the medial side of the arm and thigh, and 4000J average energy was applied per region. In the dorsal area and abdomen, 20W was adopted, and 6000J were applied in each quadrant. On average, the studied tissue's initial temperature was 31°C, and at the end of the laser application was 37°C. The temperature that caused the burn was 45°C. Conclusion: The use of the thermocamera allowed a more homogeneous distribution of the laser and provided the surgeon with effective monitoring so that an adequate dose of energy is applied to the subcutaneous and deep dermis, obtaining the desired effect.

15.
Surg. cosmet. dermatol. (Impr.) ; 13: e20210004, jan.-dez. 2021.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1368439

ABSTRACT

Introdução: a criolipólise produz um resfriamento seletivo e controlado e baseia-se no conceito de que tecidos ricos em lipídios são mais suscetíveis a lesões por frio, reduzindo gordura subcutânea. Objetivo: revisar a literatura para avaliar a eficácia da criolipólise na redução de gordura subcutânea. Métodos: revisão sistemática com metanálise de estudos publicados nas bases de dados EBSCOhost, LILACS e PUBMED. Resultados: apenas um estudo não apresentou redução significativa na gordura subcutânea quando comparado o grupo de intervenção ao grupo controle. Houve diferença entre os estudos em relação aos parâmetros. Conclusão: a criolipólise é uma ferramenta eficaz para redução de gordura localizada.


Introduction: Cryolipolysis produces selective, controlled cooling, and it's based on the concept that lipid-rich tissue is more susceptible to cold injury, reducing subcutaneous fat. Objective: To review the literature to assess the effectiveness of cryolipolysis in reducing subcutaneous fat. Methods: Systematic review with meta-analysis of studies published in the EBSCOhost, LILACS, and PUBMED databases. Results: Only one study did not present significant reduction in subcutaneous fat compared to the control group. There was a difference among the parameters in the studies. Conclusion: Cryolipolysis is an effective tool for localized fat reduction.

16.
Journal of Forensic Medicine ; (6): 351-357, 2021.
Article in English | WPRIM | ID: wpr-985224

ABSTRACT

Objective To study the correlation between the abdominal wall subcutaneous fat thickness and heart weight, so as to provide reference for prediction methods of normal range of heart weight that is suitable for autopsy in China. Methods The forensic pathology autopsy cases accepted by Center for Medicolegal Expertise of Sun Yat-sen University from 1998 to 2017 were collected. Then the exclusion criteria were determined, and according to them the total case group was selected, and the 6 disease groups and the normal group were further selected from the total case group. The rank sum test was used to compare the heart weight of the normal group and the disease groups to determine the influence of diseases on heart weight. Then the Spearman rank correlation analysis of abdominal wall subcutaneous fat thickness and heart weight in different genders and different ages in the total case group and the normal group was conducted to get the correlation coefficient (rs). Results In the total case group, correlation between abdominal wall subcutaneous fat thickness and heart weight was shown in males of all ages (P<0.05); while in females, the correlation had no statistical significance (P>0.05) in 15-<20 age and 50-<60 age, but was statistically significant (P<0.05) in other age groups. For the males in the normal group, rs was respectively 0.411, 0.541 and 0.683 in the 15-<40 age, the 40-<60 age, and the ≥60 age. For the females, rs was respectively 0.249 and 0.317 in the 15-<40 age and the 40-<60 age. The correlation in the ≥60 age had no statistical significance(P>0.05). Conclusion In the general population and the normal population, abdominal wall subcutaneous fat thickness is correlated with the heart weight of males. It is of significance to include the abdominal wall subcutaneous fat thickness in the prediction of normal range of heart weight for males in China.


Subject(s)
Female , Humans , Male , Middle Aged , Abdominal Wall/diagnostic imaging , China , Heart/diagnostic imaging , Reference Values , Subcutaneous Fat/diagnostic imaging
17.
ABCD (São Paulo, Impr.) ; 34(3): e1591, 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1355519

ABSTRACT

ABSTRACT Background: Abdominal obesity or android obesity, that is, the increase in adipose tissue in the abdominal region, is considered a risk factor for several morbidities. Different ways of quantifying it have been proposed, one method is the measurement of the abdominal fat area by computed tomography. Aim: To establish correspondence between the groups defined by degree of obesity in relation to the total, subcutaneous and visceral fat area. Methods: Cross-sectional observational study carried out through the analysis of tomographic examinations. Horos v3.3.5 medical image visualization software was used, with abdominal tomography in a single cut including the L4 vertebral body and the umbilical scar, to obtain the areas of total, visceral and subcutaneous fat. Results: Of the 40 patients, 10 had grade II obesity, 23 grade III and 7 superobese. The amount of total fat showed an increase in relation to the degree of obesity. Visceral fat did not show significant differences between the degrees of obesity, but the data showed a lower average in the group of obesity grade II. The area of subcutaneous fat, as well as total fat, showed an increase in its measurements, according to the progression of the patients' BMI, but there was no statistical significance in this difference between the groups of grade II and super-obese individuals. Conclusion: The area of total and subcutaneous fat showed an increase in its measurements according to the progression of the BMI groups, which did not happen with visceral fat.


RESUMO Racional: A obesidade abdominal ou a obesidade androide, isto é, o aumento de tecido adiposo na região abdominal, é considerada fator de risco para diversas morbidades. Diferentes formas de quantificá-la foram propostas, sendo um dos métodos a medida da área da gordura abdominal pela tomografia computadorizada. Objetivo: Estabelecer correspondência entre os grupos definidos por grau de obesidade em relação a área de gordura total, subcutânea e visceral. Métodos: Estudo observacional analítico transversal realizado através da análise de exames tomográficos. Utilizou-se software de visualização de imagens médicas Horos v3.3.5, com tomografia abdominal em um único corte incluindo corpo vertebral de L4 e a cicatriz umbilical, para obter as áreas de gordura total, visceral e subcutânea. Resultados: Dos 40 pacientes 10 apresentavam obesidade grau II, 23 grau III e 7 superobesos. A quantidade de gordura total demonstrou aumento com relação ao grau de obesidade. A gordura visceral não apresentou diferenças significativas entre os graus de obesidade, porém os dados demonstraram média menor no grupo de obesidade grau II. A área de gordura subcutânea, assim como a gordura total, apresentou aumento de suas medidas, conforme a progressão do IMC dos pacientes, porém não houve significância estatística nesta diferença entre os grupos de obesos grau II e superobesos. Conclusão: A área de gordura total e subcutânea apresentaram aumento de suas medidas conforme a progressão dos grupos de IMC, o que não aconteceu com a gordura visceral.


Subject(s)
Humans , Adipose Tissue , Obesity , Tomography, X-Ray Computed , Body Mass Index , Cross-Sectional Studies , Intra-Abdominal Fat/diagnostic imaging
18.
J. pediatr. (Rio J.) ; 96(3): 341-349, May-June 2020. tab
Article in English | LILACS, ColecionaSUS, SES-SP | ID: biblio-1135025

ABSTRACT

Abstract Objective: To assess fetal visceral adiposity and associated factors during pregnancy. Methods: Secondary analysis of prospective cohort data with 172 pairs (pregnant woman/fetus) treated at public health units. Anthropometric data, metabolic (glucose, glycated hemoglobin, insulin, insulin resistance, total cholesterol and fractions, triglycerides) measures, fetal biometry, and visceral and subcutaneous adiposity in the binomial (pregnant woman/fetus) were evaluated at the 16th, 28th and 36th gestational weeks by ultrasonography. Pearson's correlation coefficient and multiple linear regression were used, with a significance level of 5%. Results: At the 16th week, the mean age of the pregnant women was 26.6 ± 5.8 years and mean weight was 62.7 ± 11.5 kg; 47.0% had normal weight, 28.3% were overweight, 13.3% were underweight, and 11.2% were obese. At 36 weeks, 44.1% had inadequate gestational weight gain, 32.5% had adequate gestational weight gain, and 23.3% had excessive gestational weight gain. Fetal visceral adiposity at week 36 showed a positive correlation with maternal variables: weight (r = 0.15) and body mass index (r = 0.21) at the 16th; with weight (r = 0.19), body mass index (r = 0.24), and gestational weight gain (r = 0.21) at the 28th; and with weight (r = 0.22), body mass index (r = 0.26), and gestational weight gain (r = 0.21) at the 36th week. After multiple linear regression, adiposity at the 28th week remained associated with fetal variables: abdominal circumference (p < 0.0001), head circumference (p = 0.01), area (p < 0.0001), and thigh circumference (p < 0.001). At the 36th week, adiposity remained associated with the abdominal circumference of the 28th (p = 0.02) and 36th weeks (p < 0.001). Conclusion: Adiposity was positively correlated with the measurements of the pregnant woman. After the multivariate analysis, the persistence of the association occurred with the abdominal circumference, a central adiposity measurement with a higher metabolic risk.


Resumo Objetivo: Avaliar a adiposidade visceral fetal e fatores associados na gestação. Métodos: Análise secundária de dados de coorte prospectiva com 172 pares (gestantes/fetos) atendidas em unidades públicas de saúde. Foram avaliadas nas gestantes na 16a, 28a e 36a semana gestacional: medidas antropométricas, metabólicas (glicose, hemoglobina glicada, insulina, resistência à insulina, colesterol total e frações, triglicerídeos), biometria fetal e adiposidade visceral e subcutânea no binômio (gestantes/feto) por ultrassonografia. Utilizamos o coeficiente de correlação de Pearson e regressão linear múltipla, com nível de significância de 5%. Resultados: Na 16ª semana a média de idade das gestantes foi de 26,6 ± 5,8 anos e peso 62,7 ± 11,5 quilogramas, 47,0% eram eutróficas, 28,3% sobrepeso, 13,3% baixo peso e 11,2% obesas. Na 36a semana, 44,1% tiveram ganho ponderal gestacional insuficiente, 32,5% adequado e 23,3% excessivo. A adiposidade visceral fetal na 36a semana apresentou correlação positiva com variáveis maternas: peso (r = 0,15) e índice de massa corpórea (r = 0,21) na 16a; com peso (r = 0,19), índice de massa corpórea (r = 0,24) e ganho ponderal gestacional (r = 0,21) na 28a; com peso (r = 0,22), índice de massa corpórea (r = 0,26) e ganho ponderal gestacional (r = 0,21) na 36a semana. Após regressão linear múltipla a adiposidade na 28a semana permaneceu associada com variáveis fetais: circunferência abdominal (p < 0,0001), circunferência cefálica (p = 0,01), área (p < 0,0001) e circunferência da coxa (p < 0,001). Na 36a semana com circunferência abdominal da 28a (p = 0,02) e 36a semana (p < 0,001). Conclusão: A adiposidade foi positivamente correlacionada com medidas da gestante, após análise multivariada a persistência da associação deu-se com a circunferência abdominal, medida de adiposidade central, de maior risco metabólico.


Subject(s)
Humans , Female , Pregnancy , Adult , Young Adult , Adiposity , Birth Weight , Body Mass Index , Prospective Studies , Risk Factors , Obesity, Abdominal , Fetus
19.
Surg. cosmet. dermatol. (Impr.) ; 12(4): 384-387, out.-dez. 2020.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1367078

ABSTRACT

Corrigir deformidades na face ainda é um grande desafio para o cirurgião dermatológico. As opções terapêuticas podem variar conforme a etiologia, a localização, os custos e a experiência do médico-assistente. Apesar de alguns trabalhos demonstrarem controvérsias quanto aos resultados do uso de lipoenxertia autóloga (LA) para tratamento de depressões na face, relatamos um caso com bom resultado estético, após duas sessões de LA, em paciente masculino com afundamento facial após traumatismo craniano


Correcting facial deformities is still a significant challenge for the dermatological surgeon. The therapeutic options may vary depending on the etiology, location, costs, and attending physician's experiences of the. Although some studies have shown controversies regarding the results of using autologous fat transplantation (AFT) to treat facial depression, we report a case with good aesthetic results after two sessions of AFT in a male patient with a depressed facial fracture after head trauma.

20.
Article | IMSEAR | ID: sea-204697

ABSTRACT

Subcutaneous fat necrosis (SCFN) of the newborn is rare self-limited fat tissue inflammation that usually occurs in term or post-term newborns exposed to perinatal stress factors, such as perinatal asphyxia, meconium aspiration, neonatal sepsis, and therapeutic hypothermia. SCFN usually appears in the first few weeks of life and has a benign course with spontaneous resolution. Monitoring for complications, in particular the potentially life-threatening hypercalcemia, is crucial. In this report, we describe a male infant with extensive SCFN and neonatal hypercalcemia that went through a prolonged course.

SELECTION OF CITATIONS
SEARCH DETAIL